Local Irstead Area, Service

VoltVista Electric

  • Irstead
  • 10(102 reviews)

Electrical Repairs Installation of Lighting Fixtures Rewiring Fuse Box Upgrades Appliance Installation Power Outlet Installation Ceiling Fan Installation Security System Wiring Data and Networking Wiring Emergency Electrical Services Home Automation Installation Electrical Inspections Electrical Consultations Generator Installation Outdoor Electrical Work

Irstead

UK

Requirements for EV Charger Installation in the UK

Installing an Electric Vehicle (EV) charger in the UK involves several important considerations to ensure safety, compliance with regulations, and optimal performance. These requirements cover electrical standards, permits, location, and the role of qualified professionals. Here’s a detailed overview of what you need to know.

Electrical Standards and Regulations

  1. IET Wiring Regulations (BS 7671)
    • Compliance: The installation must comply with the latest edition of the IET Wiring Regulations (BS 7671). This ensures that the electrical system is safe, reliable, and efficient.
    • Earthing and Bonding: Proper earthing and bonding are crucial to prevent electric shocks and ensure safety during the use of the charger.
  2. Part P of the Building Regulations
    • Domestic Installations: All electrical installations in domestic properties must comply with Part P of the Building Regulations. This covers electrical safety and ensures that all work is certified by a competent person or inspected by local building control.
    • Certification: Electricians registered with a competent person scheme (NICEIC, NAPIT, ELECSA, STROMA) can self-certify their work, streamlining the compliance process.
  3. Electricity at Work Regulations 1989
    • Workplace Safety: For commercial installations, compliance with the Electricity at Work Regulations 1989 is essential to ensure electrical safety in the workplace.

Involvement of Qualified Professionals

  1. Certified Electrician
    • Registration: Ensure the electrician is registered with a recognized certification body and is qualified to carry out EV charger installations.
    • Experience: It’s beneficial if the electrician has specific experience with EV charger installations, as they will be familiar with the particular requirements and challenges.
  2. Site Assessment
    • Initial Consultation: The electrician should conduct a thorough site assessment to determine the best location for the charger, evaluate the existing electrical system, and identify any necessary upgrades.

Electrical Requirements

  1. Dedicated Circuit
    • New Circuit Installation: The EV charger should be connected to a dedicated circuit from the main distribution board to handle the additional load safely.
    • Circuit Breaker: Installation of an appropriate circuit breaker to protect the dedicated circuit from overcurrent, ensuring that the system is safe and compliant.
  2. RCD Protection
    • Residual Current Device (RCD): The circuit supplying the EV charger must include RCD protection to detect earth fault currents and disconnect the supply, minimizing the risk of electric shock.
  3. Earthing and Bonding
    • Proper Earthing: Ensuring the charger and the circuits are properly earthed to prevent electric shocks and ensure compliance with safety standards.
    • Supplementary Bonding: In some cases, additional bonding of metallic parts might be required to ensure safety.

Location Considerations

  1. Suitable Location
    • Accessibility: The charger should be easily accessible to the vehicle without obstructing walkways or posing a hazard.
    • Weather Protection: For outdoor installations, the charger should be weatherproof, with an appropriate IP rating to withstand environmental conditions.
  2. Proximity to Electrical Panel
    • Efficient Cabling: The closer the charger is to the main electrical panel, the less cabling is required, reducing both cost and potential voltage drop.
    • Minimizing Interference: Positioning to minimize interference with other electrical systems and ensuring efficient installation.

Permits and Notifications

  1. Building Control
    • Notification: Notify the local building control authority if the work is not being done by a certified electrician registered with a competent person scheme.
    • Inspection: Building control may need to inspect the installation to ensure it complies with the Building Regulations.
  2. Distribution Network Operator (DNO)
    • Approval: For high-power chargers, notify the local DNO, especially if the installation significantly increases the load on the electrical system. The DNO may need to approve the installation to ensure it won’t impact the local grid.

Grants and Incentives

  1. Government Grants
    • OZEV Grant: The Office for Zero Emission Vehicles (OZEV) provides grants to reduce the cost of installing EV chargers at home and workplaces. The EV Chargepoint Grant offers up to £350 towards installation costs for home chargers.
    • Workplace Charging Scheme (WCS): Provides grants for businesses covering 75% of the installation cost, up to a maximum of £350 per socket, with a limit of 40 sockets.

Installation Process

  1. Selecting the Charger
    • Type and Features: Choose the appropriate type of charger (slow, fast, or rapid) based on your needs, and consider features like smart connectivity, load management, and compatibility with your vehicle.
  2. Installation
    • Mounting the Charger: Securely mount the charger on a wall or dedicated post.
    • Connecting to Electrical System: Run the necessary cabling and make safe electrical connections to the dedicated circuit.
    • Testing and Commissioning: Perform all necessary tests to ensure the charger is operating safely and correctly before commissioning it for use.

Conclusion

Installing an EV charger in the UK involves complying with several important requirements, including adherence to electrical standards (BS 7671, Part P), involvement of qualified professionals, obtaining necessary permits and approvals, and considering location-specific factors. Utilizing available grants and incentives can help reduce the installation cost. Hiring a certified and experienced electrician ensures that the installation is carried out safely, efficiently, and in full compliance with regulations, providing a reliable and effective EV charging solution.